MIL-DTL-83298C
TABLE VII. Qualification test sequence.
Sample
Sample
Length(s)
Qty.
Test sequence - paragraph numbers
no.
type
2/
1, 2
Tube 1/
6 inch
2
3, 4
Tube 1/
14 inch
2
Hose
5, 6
Category 4
2
assembly
Hose
7, 8
Category 3
2
assembly
Hose
9, 10 3/
Category 3
2
assembly
Hose
11, 12
Category 5
2
assembly
Hose
13, 14
Category 1
2
assembly
Hose
15, 16
Category 2
2
assembly
Category 1
2
17 thru
Hose
Category 2
2
22
assembly
Category 3
2
1/ Reinforcement removed.
2/ Where applicable, categories shall be specified in table III.
3/ These samples shall have a 90° elbow fitting on one end of the assembly.
4.5 Conformance inspection.
4.5.1 Samples for conformance. Samples for conformance shall be made up of tube or hose, as specified
herein and qualified fittings from MIL-DTL-83296. Fittings may be from any one or multiple producers.
4.5.2 Individual inspection. Inspection of the product for delivery shall consist of subjecting each length of
tube and hose of each size to the individual tests specified in table VIII. Any item failing to meet the
requirements of the individual tests shall be immediately removed from the lot.
TABLE VIII. Individual inspection. 1/
Test
Requirement
Inspection or test
method
paragraph
paragraph
Examination of product
Tube roll
Tube proof pressure
Proof pressure (hose)
1/ 100% inspection required on all hose supplied to this
specification.
4.5.3 Sampling inspection. Hose lengths, randomly selected from a production lot (see 4.5.3.1) to form an
inspection sample (see 4.5.3.2), shall be subjected to the sampling tests specified in table IX.
10
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business