MIL-DTL-6000D
4.5.3 Failures. One or more failures shall be cause for refusal to grant qualification.
4.5.4 Test plans and qualification reports.
4.5.4.1 Test plans. Test plans shall be prepared and submitted in accordance with the requirements
of the qualifying activity. The method of qualification proposed by the contractor is subject to the approval
of the qualifying activity. Manufacturers shall discuss with the qualifying activity the test specimens and
test plans. These plans shall state specifically the component requirement to be verified during the test,
such as test fixtures, setup, conditions, and identification of the successor failure criteria shall be included
as appropriate.
4.5.4.2 Qualification reports. Qualification reports shall be submitted in accordance with
requirements of the qualifying activity. The examination of product shall be 100% inspection unless
another sampling plan is approved in writing by the qualifying activity.
4.6. Conformance inspection.
4.6.1. Individual inspection. Individual inspection shall consist of the inspections specified in table V
in the order shown.
4.6.1.1 Individual inspections sampling plan.
4.6.1.1.1 Individual inspection tests. Individual inspection test specified in table V shall be
performed on a production lot basis.
TABLE V. Individual inspection. 1/
Requirement
Test
Inspection
paragraph
paragraph
Examination of product
Proof pressure
1/ 100 percent inspection of bulk hose length
4.6.1.1.2 Individual inspection sampling. Individual inspection tests specified in table V shall be
performed on a production lot basis. All defective material shall be removed from the production lot and
shall not be supplied to this specification.
4.6.2 Sampling inspection. Sampling inspections shall consist of the inspections specified in table
VI and shall be made on test samples which have been subjected to and passed the individual
inspections (see table V).
4.6.2.1 Sampling inspections sampling plan.
4.6.2.1.1 Bulk hose samples. For each hose size specified in table I, samples shall be selected from
each continuous production run at the rate of one sample to be subjected to all sampling tests for each
full or partial increment of 750 feet of bulk hose produced in the continuous run, up to a maximum of 2
samples. For continuous runs greater than 1500 feet, 2 samples shall be selected, but they must be
representative of the entire run.