MIL-DTL-6000D
TABLE III. Workmanship defects.
Defect
Inspection
Reference
Dimensions affecting
Standard inspection equipment
interchangeability not within
tolerance
Ends squarely cut
Visual
Ridge on tube - Severe
Standard inspection equipment
Bunching of tube - Severe
Standard inspection equipment
N/A
Loose tube
Standard inspection equipment
N/A
Off center -under gage cover
Standard inspection equipment
N/A
Hole in tube
Standard inspection equipment
N/A
Nad lap or delamination of tube
Standard inspection equipment
N/A
Reinforcement through tube
Standard inspection equipment
N/A
Reinforcement through cover
Visual
N/A
Poorly patched cover
Visual
N/A
Blistered or loose, patch on cover
Visual
N/A
Under gage cover area
Visual
N/A
Poor coverlap, opening or lack of
Visual
N/A
adhesion
Cover missing
Visual
N/A
Loose cover (wrinkles when
Visual
N/A
bent)
Exposed reinforcement braid
Visual
N/A
Split, slit or break in cover
Visual
N/A
Blister under cover
Visual
N/A
Misbranding
Visual
4. VERIFICATION
4.1 Classification of inspection. The inspection requirements specified herein are classified as
follows:
a. Qualification inspection (see 4.5).
b. Conformance inspection (see 4.6).
4.2 Inspection conditions. Unless otherwise specified, all inspections shall be performed in
accordance with the test conditions specified in ASTM D380, ASTM D412 or in accordance with the
applicable test method referenced in the test procedure. Unless otherwise specified, room temperature
shall be 60°F to 90°F (15.56°C to 32.22°C). Where adhesion after immersion is specified, a section of
hose approximately 4 inches long shall be immersed and test specimens shall be prepared from the
center portion of this section after immersion.
4.3 Test equipment and inspection facilities. Test and measuring equipment and inspection facilities
of sufficient accuracy, quality, and quantity to permit performance of the required inspection shall be
established and maintained by the contractor. The establishment and maintenance of a calibration
system to control the accuracy of the measuring and test equipment shall be in accordance with
NCSL Z540.1 or equivalent.
7
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business