MIL-DTL-6000D
3.5.9.1 Fuel immersion. When tested as specified in 4.8.9.1, the tensile strength of the tube shall not
be less than 45 percent of the original tensile strength.
3.5.10 Elongation. When tested as specified in 4.8.10, the original ultimate elongation of the tube
shall not be less than 250 percent.
3.5.10.1 Ethylene glycol immersion. When tested as specified in 4.8.10.1, the elongation of the tube
shall not be less than 40 percent of the original elongation and in no case be less than 140 percent.
3.5.10.2 Oil immersion. When tested as specified in 4.8.10.2, the elongation of the tube shall not be
less than 40 percent of the original elongation and in no case be less than 140 percent.
3.5.10.3 Fuel immersion. When tested as specified in 4.8.10.3, the elongation of the tube shall not
be less than 50 percent of the original elongation.
3.5.11 Crush resistance. When tested as specified in 4.8.11, the crush resistance of the hose shall
not be greater than 35 pounds per linear inch to produce a 50 percent decrease of the inside diameter.
3.5.12 Water and alcohol resistance. When tested as specified in 4.8.12, the tensile loss of the tube
shall not be greater than 35 percent.
3.6 Age limits. The age of the hose shall not exceed the age limits specified in SAE-AS1933.
3.7 Identification of product. The hose shall be marked for identification in accordance with
SAE-ARP6002. In addition, each hose shall be legibly marked along the longitudinal axis with a red
stripe consisting of the Commercial and Government Entity (CAGE) code and a white stripe consisting of
the size, cure date in quarter and year, and specification (for example; Size 5/8 1Q98 6000) which shall
be repeated at least every 6 inches (15.2 mm). The hose shall be rejected when any marking is not
legible.
3.8 Workmanship. Hose shall be manufactured and processed in such a manner as to be uniform in
quality and shall be free from foreign material and other defects that will affect life, serviceability, strength,
assembly or durability (see table III). Workmanship shall be such as to enable the hose to meet the
applicable performance requirements of this specification.