3.3.4 Adapters. The hose specified herein shall be compatible with adapters in accordance with
MIL-DTL-38726.
3.3.5 Dimensions.
3.3.5.1 Length. Unless otherwise specified (see 6.2), hose shall be furnished in lengths from
20 to 65 feet (6.10 to 19.81 m). However, not more than 10% of the order may be furnished in random
lengths from 10 to 20 feet (3.05 to 6.10 m) and not more than an additional 10% may be furnished in
random lengths from 3 to 10 feet (0.91 to 3.05 m). When hose length is specified, a tolerance of ±1% of
the length shall be allowed.
3.3.5.2 Concentricity. The inside diameter and outside diameter of the hose shall be concentric within
.030 inch (0.76 mm) full indicator movement for hose sizes -2 and -3 and within .040 inch (1.02 mm) full
indicator movement for hose sizes -4, -6, -8, and -10. All readings shall be made on the end of lengths as
supplied.
3.3.5.3 Tube bore. The inside diameter of the hose shall not be reduced by more than .020 inch (0.51
mm) less than the nipple inside diameter after installation of adapters as specified in 3.3.4.
TABLE I. Hose requirements. 1/ 2/
Flexibility Kinking
Tensile
Operating
Proof
Burst
Inside
Outside
test
test
strength of
Hose
pressure,
pressure,
pressure,
diameter
diameter
weight, diameter, assembly,
size
max
min
min
(inch)
(inch)
max
max
min
(psig)
(psig)
(psig)
(lbs)
(inch)
(lbs)
.125
+ .000
-2
.375
300
600
2,000
.25
2
100
± .010
- .047
.188
+ .000
-3
.438
250
500
1,700
.25
2
100
± .016
- .047
.250
+ .000
-4
.500
200
400
1,250
.25
4
125
± .016
- .047
+ .000
.375
150
300
1,000
.56
4
150
.625
-6
- .047
± .016
.500
+ .000
-8
.781
150
250
750
1.00
6
200
± .023
- .063
.625
+ .000
-10
.906
150
250
700
2.00
6
200
± .023
- .063
See foot notes at end of table.