MIL-DTL-5593E
4.5.8 Additional QPL test and reporting requirements.
4.5.8.1 Retention of qualification. To retain qualification, the contractor shall submit a test report to
the qualifying activity at 12 month intervals. The qualifying activity shall establish the initial reporting date.
Each report shall consist of a summary of test and inspection results required by this specification that
were performed during the 12 month reporting interval. As a minimum, the report shall include the
following:
a.
Number of lots produced and tested, including lot and sample sizes for each lot.
b.
Identify which tests were performed.
c.
Quantities passed.
d.
Quantities failed.
e.
All reworked sampling lots shall be accounted for and identified. A summary of corrective
action taken shall be included.
4.5.8.2 Loss of product qualification.
4.5.8.3 Failure to meet test requirements. The manufacturer shall immediately notify the qualifying
activity at any time during the 12-month reporting period when the qualified product fails to meet the test
and inspection requirements of this specification. The manufacturer shall identify and indicate what
corrective action will be taken to correct the problem. Failure to take corrective action acceptable to the
qualifying activity may result in removal of the product from the QPL.
4.5.8.4 Failure to submit summary test data report. Failure to submit a report within 30 days after the
end of the 12 month reporting period may result in loss of qualification for the product.
4.5.8.5 Change to manufacturing process, materials or equipment. The manufacturer shall notify the
qualifying activity, in writing, of any changes in the manufacturing process, materials, or equipment used
to manufacture a QPL product. Subsequently, the qualifying activity will notify the manufacturer, in
writing, if a full re-qualification, partial re-qualification, or no additional testing is required as a result of
these changes.
4.5.8.6 No production during reporting period (12 months). When no production occurs during the
reporting period, a report shall be submitted to the qualifying activity certifying that the manufacturer still
has the capability and facilities necessary to produce the QPL product.
4.5.8.6.1 Discontinuation and resumption of production of bulk hose (three years or more). If there
has been no production of a specific size for a period of three years or more, three hose assemblies shall
each be subjected to all individual tests (table IV) and all sampling tests (table V), and four samples shall
be subjected to each periodic test (table V) before production is resumed.
4.6 Test methods.
4.6.1 Examination of product. Each length of hose shall be visually examined for conformance to the
following requirements: