MIL-DTL-17505F
4.4 Component and material inspection. Components and materials shall be inspected in
accordance with all the requirements specified herein and in applicable referenced documents.
4.5 Sampling. Sampling and inspection procedures shall be in accordance with ANSI Z1.4. All
hose and hose assemblies of the same type and size offered for delivery at one time shall be
considered a lot for the purpose of inspection.
4.5.1 Sampling for examination. Guidance for inspection level and an Acceptance Quality Level
(AQL) is provided in 6.6.1.
4.5.2 Sampling for tests.
4.5.2.1 Sampling for length, inside diameter, resistance to vacuum, minimum bend and kink
test. Guidance for inspection level and AQL is provided in 6.6.2.
4.5.2.2 Sampling for hydrostatic and electrical conductivity tests. All hose submitted shall be
subjected to the hydrostatic and electrical conductivity tests specified in 4.7.5.
4.5.2.3 Sample for adhesion tests. A 2-foot (610 mm) length of hose identical to the hose
submitted for the lot, except that it shall be without helix wire and nipples, shall be submitted for
the adhesion tests specified in 4.7.14 and 4.7.15.
4.5.2.4 Sample for wire tests. The manufacturer shall submit 6 feet (1 829 mm) of wire taken
from the same lot of wire used in the manufacture of the hose submitted for the tensile strength
and flexibility test specified in 4.7.18.
4.5.2.5 Sample for physical tests. An 8-foot (2 438 mm) length of hose with couplings identical
to the hose submitted for the lot shall be submitted for the burst test specified in 4.7.7. At the
completion of the burst test, additional tests shall be conducted as specified in 4.7.3, 4.7.9 through
4.7.13, 4.7.16, and 4.7.17 on an undamaged section of the 8-foot (2 438 mm) sample of hose
submitted for the burst test.
4.6 Examination. Each of the sample hose lengths selected shall be visually and dimensionally
examined to determine conformance with all the requirements of this specification not involving
tests. The classification of defects in FED-STD-162 shall be used to determine and evaluate
defects through visual inspection. In addition to the defects listed in FED-STD-162, the hose
sample shall be examined for the following defect: (Minor) Marking not as specified (see 3.14).
4.7 Tests.
4.7.1 Length. Hose selected shall be measured for length including fittings (see 3.3).
4.7.2 Inside diameter. Hose selected shall have the id measured in accordance with
ASTM D 380 to determine conformance to table II.