A-A-52426A
TABLE V. Hose diameter tolerances (types IV).
Nominal Size I.D. (inch) |
Inside diameter Tolerance (inch) |
1/2 |
+.039 -.000 |
5/8 |
+.042 -.000 |
7/8 |
+.042 -.000 |
1 1/8 |
+.047 -.000 |
TABLE VI. Wall thickness limits (types I and II).
Inside diameter |
Minimum (inch) |
Maximum (inch) |
All sizes |
.170 |
.220 |
TABLE VII. Wall thickness limits (type IV).
Size (inch) |
Minimum (inch) |
Maximum (inch) |
1/2 |
.144 |
.166 |
5/8 |
.144 |
.166 |
7/8 |
.142 |
.168 |
1 1/8 |
.155 |
.177 |
TABLE VIII. Tolerance on hose lengths (types I, III, & IV).
Over |
To and including |
Tolerance |
(inch) |
(inch) |
(inch) |
-- |
12 |
+3/16 -1/16 |
12 |
24 |
+1/4 -1/8 |
24 |
-- |
+1/2 -1/4 |
TABLE IX. Tolerances on preformed (type II) hose length.
Each end (measured from end to intersect of nearest centerline) |
(inch) |
+3/16 - 1/8 |
3.2.7 Hose length.
3.2.7.1 Type I. Unless otherwise specified (see 6.2), type I bulk hose shall be furnished in lengths of 3, 25 or 40 feet, or multiples thereof.
3.2.7.2 Type IV. Specify the length of type IV hose required in feet (see 6.2). The hose length includes the length of the steel end fittings.