A-A-52426A
TABLE II. End fitting flares.
End fitting flare |
Type IV hose ID |
45° |
.5 |
45° |
.625 |
37° |
.875 |
37° |
1.125 |
3.2.6 Dimensions.
3.2.6.1 Diameter tolerances. Tolerances for hose diameters shall be as shown in tables III, IV and V.
TABLE III. Hose diameter tolerances (types I and II).
Inside diameter |
Tolerances |
||
From |
To and including |
Straight hose |
Curved hose |
(inch) |
(inch) |
(inch) |
(inch) |
3/8 |
1/2 |
±1/64 |
±1/32 |
3/8 |
4 |
±1/32 |
±1/32 |
TABLE IV. Hose diameter tolerances (type III).
Inside diameter |
Outside diameter |
||
(Hose & Cuff) |
Tolerance |
(Cuff only) |
Tolerance |
(inch) |
(inch) |
(inch) |
(inch) |
1 1/4 |
+1/64 -1/32 |
1 5/8 |
+1/16 -0 |
1 1/2 |
+1/64 -1/32 |
2 |
+1/16 -0 |
1 3/4 |
+1/64 -1/32 |
2 1/4 |
+1/16 -0 |
2 |
+1/64 -1/32 |
2 1/2 |
+1/16 -0 |
2 1/4 |
±1/32 |
2 7/8 |
+1/16 -0 |
2 1/2 |
±1/32 |
3 1/8 |
+1/16 -0 |
3 |
±1/32 |
3 3/4 |
+1/16 -0 |
4 |
±1/32 |
4 3/4 |
+1/16 -0 |
3.2.6.2 Wall thickness. Types I, II, and IV hose wall thickness shall be within limits shown in tables VI and VII. Type III hose wall thickness shall be uniform and wire shall not be exposed.
3.2.6.3 Tolerance on lengths. Tolerances on types I, III, and IV for specified (cut) lengths shall be as specified in table VIII, and on type II hose (preformed) shall be as shown in table IX.