MS8006C
Protective sleeve code: See table XIII.
TABLE XIII. Protective sleeve code.
Code |
Type |
A |
SAE AS1072 sleeve, fire protection, silicone covered, temperature ranging from -65°F to 450°F, and intermittently to 500°F, secured with CRES bands as required. 1/ |
B |
SAE AS1073 - code B sleeve, abrasion protection, heat shrinkable, black polyolefin, temperature ranging from -65°F to 250°F. |
C |
SAE AS1291 - code A sleeve, chafe guard, extruded seamless white PTFE, temperature ranging from -65°F to 450°F, secured with CRES bands as required. |
D |
SAE AS1291 - code C sleeve, chafe guard, extruded seamless transparent FEP, temperature ranging from -65°F to 350°F, secured with CRES bands as required. |
E |
SAE AS1298 sleeve, heavy wall chafe guard, extruded seamless black PTFE, temperature ranging from -65°F to 450°F, secured with CRES bands as required. |
L |
Lock-wire hole |
F |
Code A + L |
G |
Code B + L |
H |
Code C + L |
J |
Code D + L |
K |
Code E + L |
1/ To prevent wicking of fluids, the cut end of the fire protective sleeve (code A) shall be coated with
Room Temperature Vulcanized (RTV) silicone rubber prior to installation. After installation, cracks and voids in the fire protective sleeve shall be coated with RTV rubber to prevent exposure of asbestos or fiberglass.
13
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business