MIL-PRF-62028D
90-day test, sample number 8 shall be subjected to, and pass, the tests as specified in 4.3.3.1 and
4.3.3.2.
4.3.6.5 Ozone resistance. The hose shall be subjected to the applicable test as specified in
ASTM D1171. Subsequent to testing, evidence of cracks or breaks shall constitute failure of this
test.
5. PACKAGING
5.1 Packaging. For acquisition purposes, the packaging requirements shall be as specified
in the contract or order (see 6.2). When actual packaging of material is to be performed by DoD
personnel, these personnel need to contact the responsible packaging activity to ascertain requisite
packaging requirements. Packaging requirements are maintained by the Inventory Control Point's
packaging activity within the Military Department of Defense Agency, or within the Military
Department's System Command. Packaging data retrieval is available from the managing Military
Department's or Defense Agency's automated packaging files, CD-ROM products, or by
contacting the responsible packaging activity.
6. NOTES
(This section contains information of a general or explanatory nature that may be helpful,
but is not mandatory.)
6.1 Intended use. The hose covered by this specification is intended for use in
heat-transfer applications in military vehicles. The hoses covered by this specification are military
unique because they must be able to operate satisfactorily at ambient temperatures ranging from -
65oF to +600oF. Commercial components are not designed to withstand such extreme
environmental conditions and would experience failure.
6.2 Acquisition requirements. Acquisition documents should specify the following:
a. Title, number, and date of this specification.
b. Type and class of the hose required (see 1.2).
c. Issue of DoDISS to be cited in the solicitation, and if required, the specific issue of
individual documents referenced (see 2.2).
d. If first article inspection is required (see 3.1 and 6.4).
e. Specification of interface drawing(s) (see 3.4.1 and 4.3.4).
f. If identification marking is other than as specified (see 3.5 and 4.3.5).
g. Specification of contractual sampling plan (see 4.1.2 and 6.5).
h. If inspection conditions are other than as specified (see 4.3.2).
i. Packaging requirements (see 5.1).
j. Part or identifying number (see 6.3).
9