MIL-PRF-62028D
3.6.4 Fungus resistance. The hose shall show no evidence of fungal growth when
subjected to environments conducive to spore germination and growth (air temperature between
35 and 100°F and relative humidity between 60 and 100%).
3.6.5 Ozone resistance. The hose shall not crack or break when subjected to a minimum
of 72 hours of ozone exposure at 104 ± 2°F, with a partial ozone pressure of 50 ± 5 millipascals
(mPa).
4. VERIFICATION
4.1 Classification of inspection. The inspection conditions specified herein are classified
as follows:
a. First article inspection (see 4.1.1).
b. Conformance inspection (see 4.1.2).
4.1.1 First article inspection. First article inspection shall be performed on the first nine
production-representative units of an order when a first article sample is required (see 3.1).
Inspection shall include all the verifications listed in table III and shall be in the order as specified
in table IV.
TABLE III Verification methods.
Title
Requirement
Verification
Operating requirements
3.3
4.3.3
Leakage
3.3.1
4.3.3.1
Proof & burst pressures
3.3.2
4.3.3.2
Vacuum resistance
3.3.3
4.3.3.3
Flexibility
3.3.4
4.3.3.4
Collapsing resistance
3.3.5
4.3.3.5
Interface requirements
3.4
4.3.4
Envelope and interface dimensions
3.4.1
4.3.4.1
Interchangeability
3.4.2
4.3.4.2
Support and ownership requirement
3.5
4.3.5
Operating environment requirements
3.6
4.3.6
High temperature resistance
3.6.1
4.3.6.1
Low temperature resistance
3.6.2
4.3.6.2
Vibration resistance
3.6.3
4.3.6.3
Fungus resistance
3.6.4
4.3.6.4
Ozone resistance
3.6.5
4.3.6.5