MIL-DTL-8795G
TABLE III. Periodic sampling inspection.
Requirement
Inspection
Periodic inspection
paragraph
paragraph
Bulge
Leakage
Burst pressure
4.1.2.3 Non conformance sampling and periodic inspections. In the event a failure should occur
during periodic sampling inspection tests, specified in table III, then the production lot shall be screened
for that particular defect and defects removed. An inspection lot shall be selected from the production lot
and all periodic sampling tests shall be performed. If one or more defects are found in the second
inspection lot, the production lot shall be rejected and shall not be supplied to this specification. Test data
of part performance shall be made available to the contracting agency upon request.
4.1.2.4 Disposition of test specimens. Test specimens that have been subjected to periodic
sampling inspection in table III shall not be delivered on the contract or purchase order.
4.2 Test equipment and inspection facilities. Test and measuring equipment and inspection facilities
of sufficient accuracy, quality, and quantity to permit performance of the required inspection shall be
established and maintained by the contractor. The establishment and maintenance of a calibration
system to control the accuracy of the measuring and test equipment shall be in accordance with
NCSL Z540.3 or equivalent.
inspection set forth in this specification shall become a part of the contractor's overall inspection system
or quality program. The absence of any inspection requirements in the specification shall not relieve the
contractor of the responsibility of ensuring that all products or supplies submitted to the Government for
acceptance comply with all requirements of the contract. Sampling inspection, as part of manufacturing
operations, is an acceptable practice to ascertain conformance to requirements, however, this does not
authorize submission of known defective material, either indicated or actual, nor does it commit the
Government to accept defective material.
4.4 Sample preparation.
4.4.1 Inspection conditions. Unless otherwise specified, all inspections shall be performed in
accordance with the test conditions specified in ASTM D380, or in accordance with the applicable test
method referenced in the test procedures. Unless otherwise specified, room temperature shall be defined
as +60°F to +90°F (15.56°C to 32.22°C).
4.4.2 Test fluid. The test fluid shall be water; lubricating oil conforming to SAE J1966, grade 50;
hydraulic fluid in accordance with MIL-PRF-5606, MIL-PRF-87257 or MIL-PRF-83282; or fuel in
accordance with ASTM D471, ASTM Reference fuel B. Water is an acceptable test fluid only for the
leakage, proof pressure, and burst tests. If water is used, the test article must be thoroughly dried before
use in further testing or prior to delivery.
4.5 Methods of examinations and tests.
4.5.1 Examination of product. Each hose assembly and its related manufacturing records shall be
examined for compliance with the requirements specified herein with respect to dimensions, materials
7
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business