MIL-H-23799 (Wep)
Temperature and pressure - Unless otherwise specified,
4.6.2
tests shall be conducted at an ambient temperature of 77 ±18°F and at an
ambient barometric pressure of 28 to 32 inches of mercury. If tests are
conducted at different ambient conditions, appropriate correction factors
shall be applied to the flow and pressure readings. All specified test pres-
sures are gage pressures measured relative to the ambient air pressures,
4.7
Inspection methods -
4.7.1
Visual examination -
Hose - Every hose shall be checked dimensionally and exami-
4.7.1.1
ned visually to determine conformance to this specification and applicable draw-
ings. The classification of defects. Tables II and III, shall be used to classify
the defects found.
TABLE II
CLASSIFICATION OF DEFECTS FOR VISUAL EXAMINATION OF THE HOSE
ASSEMBLY