MIL-DTL-81581/8A
4.3.2 First article inspection. The first article inspection of the hose assembly shall consist
of the applicable examinations and tests specified in the general specification with the applicable
procedure as specified herein.
4.3.2.1 First article samples. The first article sample shall consist of four hose assemblies
of each style contracted for.
4.3.3 Conformance inspection. The conformance inspection shall consist of the inspections
specified in table I.
TABLE I. Sample size, acceptance criteria, tests and examinations of the cable assemblies.
TEST
SAMPLE
1/
INSPECTION
REQUIREMENT
METHOD
SIZE
Visual examination
-
4.4.1.1
Every cable assembly
(See classification of
for critical defects.
defects)
Inspection Level II for
minor defects.
Flexibility
3.6.8
4.4.9
Inspection Level S-2
Cable tensile strength
3.6.2
4.4.3
Inspection Level S-2
Insulation resistance
3.6.3
4.4.4
Inspection Level S-2
Polarity and electrical
3.6.4
4.4.5
Every cable assembly
continuity
1/ Sampling for acceptance inspection shall be in accordance with ASQ-Z1.4.
4.4 Inspection methods.
4.4.1 Visual examination.
4.4.1.1 Cable assembly. Every cable assembly shall be examined visually for critical
defects to determine conformance to this specification and applicable drawings. The
classification of defects, table II, shall be used to classify the defects found, as applicable.