MIL-DTL-81581/5B
High temperature, Procedure I
Flexibility endurance, Procedure II
Ozone resistance, Procedure II
Weight, Procedure I
4.1.1.1 Qualification samples. The qualification samples shall be as specified in
MIL-DTL-81581 with the following exception: Four 36-inch long hose assemblies of each type
and style for which qualification is desired.
4.1.2 First article inspection. The first article inspection of the hose assembly shall consist
of the applicable examinations and tests specified in the general specification with the applicable
procedure as specified herein.
4.1.2.1 First article samples. The first article sample shall consist of four hose assemblies
of each style contracted for.
4.1.3 Conformance inspection. Conformance inspection shall consist of the following tests
from the general specification. The sample size and acceptance criteria shall be as specified in
the general specification.
Visual examination
Polarity (color code) and electrical continuity, Procedure I
Insulation resistance, Procedure I
Elongation, Procedure II
Delamination, Procedure I
Odor, Procedure I
Cleanliness, Procedure I and II
Leakage, Procedure II
Flexibility
Type I, Procedure II
Types II and III, Procedure IV (under environmental conditions, Procedure III)
Packaging
5.
PACKAGING
5.1 Packaging. Packaging shall be in accordance with the general specification.
6.
NOTES
(This section contains information of a general or explanatory nature that may be helpful,
but is not mandatory.)