MIL-DTL-81581/4B
Maximum
Type
weight in ounces
I
5.0
II
9.0
4.
VERIFICATION
4.1 Sampling and inspections. Sampling and inspections shall be in accordance with the
general specification and as specified herein.
4.1.1 Qualification inspection. The qualification inspection of the hose assembly shall
consist of the following examinations and tests from the general specification:
Visual examination
Polarity (color code) and electrical continuity, Procedure I (Type II only)
Insulation resistance, Procedure I (Type II only)
Elongation, Procedure II
Delamination, Procedure I
Odor, Procedure I
Cleanliness, Procedure I and II
Leakage, Procedure II
Flexibility, Procedure IV (for environmental conditions, Procedure II)
Minimum burst pressure, Procedure II
Tensile load, Procedure V
Restraint cord elongation and tensile strength
Static load, Procedure I
Low temperature, Procedure I
High temperature, Procedure I
Flexibility endurance, Procedure II
Ozone resistance, Procedure II
Abrasion, Procedure I
Weight, Procedure I
4.1.2 First article inspection. The first article inspection of the hose shall consist of the
applicable examinations and tests specified in the general specification with the applicable
procedure as specified herein.
4.1.2.1 First article samples. The first article sample shall consist of four hose assemblies
of the part number contracted for.